Code,Standards,Practices 2 Lvl1 Lesson 2-B

1
2
3
4
5
6
7
8
9
10
Across
4
100, A Single Outlet Device can be Multiple Receptacles with Two or More Contact Devices on the Same Mounting Yoke Strap
5
210.4(C) Multiwire Branch Circuits Shall Supply Only Line to Neutral Loads
6
210.23 (A-D), 210.24, In No Case Shall the Load Exceed the Branch Circuit Ampere Rating
7
210.23(2), The Total Rating of Utilization Equipment Fastened in Place, Other than Luminaires Shall Not Exceed 50 percent of the Branch Circuit
8
200.6, An Insulated Grounded Conductor 6 AWG or Smaller Shall be Identified by (1-8) Using Continuous White, Gray, W/G Stripes, ETC...
9
210.8(A), Dwelling GFCI Installed Within 6 feet of Water, Un finished Basements, Boathouses, and Not Required in Finished Basements
10
210.21(B)(2), 15 Ampere Receptacle Protected by 15 A or 20 A Overcurrent Device
Down
1
210.19(A)(3)Exp.1, The Dwelling Conductors Supplying a 50 Amp Oven Can Feed a Stovetop with a Minimum of 20 Amp or Load
2
210.19(A)(3), Household Ranges Branch Circuit Conductors Based on Nameplate and if more than 8 3/4 KW Minimum 40 Amperes
3
210.25(A), Branch Circuits in Each Dwelling Shall Supply only Loads Within that Dwelling Unit