ELTT Code Crossword

Across
Insulation with flame retardant properties 4,7 (0)
No point in a ____ shall be more than 4.5m from a particular electrical device (26)
What do the letters "WP" marked on a motor indicate (2)
The heating portion of heating cable sets and heating panel sets shall not penetrate or pass through walls, partitions, ____, or similar structures (62)
Point in the wiring installation at which current is taken to supply utilization equipment (0)
Lighting branch circuits shall be kept entirely separate from ____ branch circuits (76)
The _____ heating circuit, including the conductors and pipe, vessel or structure, shall not be bonded to ground 5,3,7 (62)
Grounding conductor shall be electrically ____ (10)
You cant run Class 1 circuits in the same ____ as communication circuits (16)
Is it permissible to use luminaires of the pendant type in clothes closet (30)
Circuit breakers shall be of the ____4,4 type (14)
Grounding electrodes can be manufactured, field assembled or ____2,4 (10)
Down
What is the maximum sized wire for cellular floors 1,3 (12)
What colors should be used for a single phase 3 wire circuit that employs an identified conductor 5,3,5 (4)
What must be provided at the supply end of a consumers service 7,4 (6)
The load of lighting and receptacle circuits, based on the outside dimensions of a specific area of building occupancy, as listed in table 14. 5,4 (8)
Maximum volts to ground in dwelling unit branch circuits 3,5 (30)
The electric vehicle energy management system is provided with a maximum load rating, which determines the branch circuit, ____ and service loading (8)
What needs to be mounted to a surface extension made from an existing outlet 9,4 (12)
What is the minimum size equipment wire that can be used for Christmas tree wiring 2,3 (4)
No ____ device shall be positioned more than 1.7m above finished floor (26)
What type of material should a service mast be made from (6)
"T" rated switches are to be used for _____ filament lamp loads (14)
A safety control devide is deemed to be a Class 1 circuit when its failure to operate will induce a ____ (16)
Where service equipment is installed in an outdoor location it shall be capable of being ____ (76)
Unless otherwise specified, when the code makes reference to AWG size, to what material are they inferring (2)