The Best Crossword Puzzle Maker Online
Powered by BrightSprout
Save Status:
or to save your progress. The page will not refresh.
Controls:
SPACEBAR SWITCHES TYPING DIRECTION
Answer Key:
Edit a Copy:
Make Your Own:
Crossword Word Search Worksheet
Rate This Puzzle:
Log in or sign up to rate this puzzle.

Pedimag

Alarms and Alerts ( Section 8: Operation ) 
Across
If the blood pump has been stopped over ___ minutes, do not restart WITHOUT PROPER ANTICOAGULATION
Overheating is confirmed by a ___ ___ ___ alert message and temperature sufficient to prevent user from placing and holding a hand on the motor housing
In the case of an ALERT, the operator may mute the audible alert, which silences the audible but the visual message remains; however, the pump will not ___
The only exception to audio alarm alert silencing is ____. This alarm cannot be silenced until console is plugged into AC power
____ advisories activate when the system is about to or has entered, an unsafe state of operation that is hazardous to the patient, operator, or device (red state). Except for the motor ALARM event, all events in this condition will STOP the pump.
If during start up, you receive the alarms 1. _____ or 2. Power on test fail, do the following steps. 1)Turn the Power switch off 2) check all cable connections 3)Turn the power switch back on. If the alarm re-occurs, use another CONSOLE and MOTOR. Do not use the suspect Console or Motor as main or backup unit.
A normal operating condition is free of any alerts or alarms and is classified as ___ state of operation
Down
DO NOT restart the pump if it has stopped due to Motor _____. Just clamp the return tubing and switch to the backup motor.
In the case of an ALARM, the user may acknowledge the alarm, but the visual message will still be displayed, but will not allow ___ to occur until the alarm condition no longer exists.
In the event of a ___ condition, the operator is warned that the system is about to, or has entered, an unsafe but resolvable operating state and the pump will keep working (yellow state)
If the pump has been stopped for over 5 minutes, there is an increased risk of ____
In order to manually shut the pump off, you must hold down the STOP key for _____ seconds
The recommended action by the operator during an ALARM CONDITION is to rapidly assess the situation and respond to the cause of the alarm. If equipment change is necessary, ___ the return tubing before switching to the backup equipment. Always unclamp the tubing before resumption of pumping
To start operation of the blood pump when using a very small cannula, RPMs of ___ hundred may be required
There are ___ high priority alarms that may not be muted; POWER ON TEST FAIL, SYSTEM FAULT, MOTOR ALARM. The visual alarm and audio will be removed if 1) The condition was acknowledged by decompressing the Alarm acknowledge button and 2) The condition was actually resolved