HEALTHCARE ELECTRICAL

For Hospital Facilities Departments Electrcial Knowledge Puzzle
Across
NFPA 99, 2012 6.3.3.2.3 states that the correct _ of the hot and neutral connections in each electrical receptacle shall be confirmed by visual inspection
The acronym that refers to healthcare assessments covering potential risks, to patients, staff, visitors or assets for air quality, infection control, utility requirements, noise, vibration and any other hazards applicable to the work being done.
NFPA 99, 2012 6.3.3.2.4 states that _ _ of the grounding blade of each electrical receptacle (except locking-type receptacles} shall not be less than 115 g (4 oz.).
According to NFPA 99, 2012 6.3 _ testing in patient care rooms needs to be done annually.
What is the acronym referenced in NFPA 99 -3.3.95 “A test instrument designed to continually check the balance and unbalanced impedance from each line of an isolated circuit to ground and equipped with a built-in test circuit to exercise the alarm without adding to the leakage current hazard.”
According to NFPA 99-3.3.95 how often does a line isolation monitor needs to be tested.
Acronym for National Electrical Code
The Joint Commission standard EC.02.05 07 EP7 requires that all automatic transfer switches are tested _
What label or mark specfiies a hospital grade outlet or receptacle
What entitiy standards are the basis of an objective evaluation process that can help healthcare organizations assess and improve performance. The standards focus on important patient, individual, or residential care. They give attention to the facility functions that are essential to providing safe, high quality care.
NFPA 99 2018 Edition 6.3.2.3.4 states: “_ _ shall be considered to be a wet procedure location, unless a risk assessment conducted by the health care governing body determines otherwise.”
Down
NFPA 99, 2012 6.3.3.2.1 states that _ _ of each receptacle shall be confirmed by visual inspection.
NFPA 99, 2012 6.3.3.2.2 states that the _ of the grounding circuit in each receptacle shall be verified.
What Louisiana Government Agency has compliance with healthcare facility licensing requirements on behalf of the Department of Health and Hospitals
What is another name for the test that measures resistance between any two points separated by electrical insulation. Also known as a Megger Test.
NFPA 99, 2012 6.3.3.2.4 states that _ _ of the grounding blade of each electrical receptacle (except locking-type receptacles} shall not be less than 115 g (4 oz.).
_ _ shall be periodically tested in accordance with NFPA 110.
What is the meaning of IG wiring and receptacles used in healthcare.
Acronym denoting the safety process for isolation of electrical energy